Report 1:EMS-2000 Adv. Stack Diagnostics, Top 20 Largest NOX sources in the State of illinois 1 Verify that these totals are correct, and that none are missing 17:20 Monday, December 5, 2011 State total emissions are 269 Tons/Day NOX and 5 Tons/Day ROG A complete list of all sources summarized by this report are in illinois_long.lst State = illinois State FIPS = 17 NOX ROG Obs cntryid STID CYID fcid name TONS/DAY TONS/DAY 1 US 17 179 179801AAA Midwest Generation LLC 61.446 0.25147 2 US 17 197 197810AAK Will County Electric Generatin 28.170 0.06942 3 US 17 137 137805AAA Ameren Energy Generating Co 20.760 0.13851 4 US 17 197 197809AAO Midwest Generation LLC 19.640 0.01030 5 US 17 127 127855AAC Electric Energy Inc 15.121 0.48033 6 US 17 97 097190AAC Waukegan Electric Generating S 14.087 0.01528 7 US 17 157 157851AAA Dynegy Midwest Generation Inc 12.867 0.92809 8 US 17 79 079808AAA Ameren Energy Generating Co 12.671 0.43851 9 US 17 143 143805AAG Ameren Energy Resources Genera 12.124 0.27298 10 US 17 167 167120AAO City Water Light Power 11.488 0.18112 11 US 17 135 135803AAA Ameren Energy Generating Co 9.442 0.25950 12 US 17 119 119020AAE Dynegy Midwest Generation Inc 7.216 0.16501 13 US 17 21 021814AAB Kincaid Generation LLC 7.108 0.62125 14 US 17 31 031600AIN Crawford Electric Generating S 6.274 0.00475 15 US 17 33 033801AAA Ameren Energy Generating Co 3.758 0.04870 16 US 17 31 031600AMI Fisk Electric Generating Stati 3.577 0.00309 17 US 17 155 155010AAA Dynegy Midwest Generation Inc 3.447 0.10929 18 US 17 199 199856AAC Southern Illinois Power Coop 3.099 0.16451 19 US 17 183 183814AAA Dynegy Midwest Generation Inc 3.066 0.03677 20 US 17 149 149817AAB Soyland Power Coop 2.615 0.00725 ======== ======== 257.977 4.20616 Report 1:EMS-2000 Adv. Stack Diagnostics, Top 10 Largest ROG sources in the State of illinois 2 Verify that these totals are correct, and that none are missing 17:20 Monday, December 5, 2011 State total emissions are 269 Tons/Day NOX and 5 Tons/Day ROG A complete list of all sources summarized by this report are in illinois_long.lst State = illinois State FIPS = 17 NOX ROG Obs cntryid STID CYID fcid name TONS/DAY TONS/DAY 1 US 17 157 157851AAA Dynegy Midwest Generation Inc 12.867 0.92809 2 US 17 21 021814AAB Kincaid Generation LLC 7.108 0.62125 3 US 17 127 127855AAC Electric Energy Inc 15.121 0.48033 4 US 17 79 079808AAA Ameren Energy Generating Co 12.671 0.43851 5 US 17 143 143805AAG Ameren Energy Resources Genera 12.124 0.27298 6 US 17 135 135803AAA Ameren Energy Generating Co 9.442 0.25950 7 US 17 179 179801AAA Midwest Generation LLC 61.446 0.25147 8 US 17 167 167120AAO City Water Light Power 11.488 0.18112 9 US 17 119 119020AAE Dynegy Midwest Generation Inc 7.216 0.16501 10 US 17 199 199856AAC Southern Illinois Power Coop 3.099 0.16451 ======== ======== 152.583 3.76279 Report 2:EMS-2000 Adv. Stack Diagnostics, Potential Problems, High Priority Stacks(all >1 TPD) 5 State total emissions are 269 Tons/Day NOX and 5 Tons/Day ROG 17:20 Monday, December 5, 2011 These records are only possible problems which fall outside standard ranges State = illinois State FIPS = 17 ' FLOW FLOW Estimated NOX ROG DIAM HEIGHT TEMP CALCULATED VELOC REPORTED Plume Heit Tests Obs CYID fcid name stkid TONS/DAY TONS/DAY (FEET) (FEET) F ACFM FEET/SEC ACFM (Meters) Failed 1 179 179801AAA Midwest Generation LLC 18 61.422 0 34.0 500 308 1781321 32.7 1781321 1229.82 e F 2 135 135803AAA Ameren Energy Generating Co 2 6.165 0 29.0 500 349 2251028 56.8 2251028 1473.02 e F 3 79 079808AAA Ameren Energy Generating Co 12 5.936 0 24.0 530 317 2054731 75.7 2054731 1353.05 e F 4 197 197810AAK Will County Electric Generatin 11 5.731 0 16.5 500 325 1091777 85.1 1091777 978.52 e F 5 157 157851AAA Dynegy Midwest Generation Inc 13 5.530 0 19.5 605 306 1576843 88.0 1576843 1182.45 e F 6 197 197809AAO Midwest Generation LLC 16 5.367 0 17.0 550 350 1198442 88.0 1198442 1073.97 e F 7 127 127855AAC Electric Energy Inc 1 5.346 0 18.0 550 310 1299305 85.1 1299305 1062.45 e F 8 127 127855AAC Electric Energy Inc 2 4.923 0 18.0 550 310 1299305 85.1 1299305 1062.45 e F 9 127 127855AAC Electric Energy Inc 3 4.851 0 18.0 550 310 1299305 85.1 1299305 1062.45 e F 10 197 197809AAO Midwest Generation LLC 17 4.307 0 17.0 550 350 1198442 88.0 1198442 1073.97 e F 11 21 021814AAB Kincaid Generation LLC 7 4.041 0 29.6 613 288 3633312 88.0 3633312 1779.73 e F 12 157 157851AAA Dynegy Midwest Generation Inc 1 3.669 0 19.5 605 308 1576843 88.0 1576843 1185.89 e F 13 157 157851AAA Dynegy Midwest Generation Inc 2 3.668 0 19.5 605 303 1576843 88.0 1576843 1177.23 e F 14 135 135803AAA Ameren Energy Generating Co 1 3.275 0 29.0 500 349 2251028 56.8 2251028 1473.02 e F 15 21 021814AAB Kincaid Generation LLC 16 3.059 0 16.6 492 278 1044020 80.4 1044020 889.51 e F 16 125 125804AAB Dynegy Midwest Generation Inc 19 1.649 0 20.0 502 340 1521143 80.7 1521143 1183.87 e F 17 183 183090AAE Dynegy Midwest Generation Inc 1 1.609 0 10.0 45 835 57962 12.3 57962 215.85 e H ======== ======== 130.549 0 NON-EGU Tests E=Emis/flow > 20 G Nox/acfm e= Emis/flow < .5 G NOX/ACFM C=calculated flow rate Problem V=Velocity gt 100 ft/sec F=Flow rate > 1000000 ACFM H = Plume height 3X stack height EGU Tests E=Emis/flow > 40 G Nox/acfm e= Emis/flow < .5 G NOX/ACFM C=calculated flow rate Problem V=Velocity gt 140 ft/sec F=Flow rate > 3000000 ACFM H = Plume height 3X stack height Report 3: EMS-2000 Adv. Stack Diagnostics, Automated Stack Repair, summary statistics 6 The Model will re-assign these elevated stacks to the surface layer if the Active-ASD processor is run (all have less than 1 TPD NOX, stack height less than 33 Meters(108 feet) and a plume height greater than 100 meters) A complete list of all sources summarized by this report are in illinois_long.lst 17:20 Monday, December 5, 2011 State = illinois State FIPS = 17 FIPS Number Number of Tests NOX ROG Obs State stname Of Stacks Failed Tests Failed TONS/DAY TONS/DAY 1 17 Illinois 179 2 e H 1.33759 0.11308 2 17 Illinois 22 3 e FH 0.13588 0.00569 ========= ======== ======== 201 1.47347 0.11877 NON-EGU Tests E=Emis/flow > 20 G Nox/acfm e= Emis/flow < .5 G NOX/ACFM C=calculated flow rate Problem V=Velocity gt 100 ft/sec F=Flow rate > 1000000 ACFM H = Plume height 3X stack height EGU Tests E=Emis/flow > 40 G Nox/acfm e= Emis/flow < .5 G NOX/ACFM C=calculated flow rate Problem V=Velocity gt 140 ft/sec F=Flow rate > 3000000 ACFM H = Plume height 3X stack height